  • Size: 2, 4, 8, or 16 zones (conventional) or 1 to 4+ loops (addressable).
  • Devices: Up to 32 devices per zone or 250 per loop.
  • Mains: 230V AC, 50Hz primary power input.
  • Backup: 24V DC battery setup with automatic charger.
  • Body: Wall-mounted powder-coated MS sheet enclosure.
  • Interface: LCD display with Reset, Silence, and Test keys

PA (Public Address); FA (Fire Alarm) Panel

  • Integration: PA system links to the FA panel via NO/NC relay contacts for automated evacuation announcements.
  • FA Panel Type: Addressable or Conventional (2/4/8/16+ zones) loop-based control system.
  • FA Power & Backup: 230V AC mains input with a built-in 24V DC battery charger and 24-to-48-hour standby backup.
  • PA Amplifier Output: 120W / 250W / 500W+ (70V / 100V line) options depending on zone speaker loads.
  • PA Enclosure & Controls: 14/16 SWG wall-mounted rack with zoning switches, gooseneck fireman mic, and pre-recorded alert messages.
  • Standards: Conforms to IS 2189 (FA system code) and NBC (National Building Code) requirements.

VIRE-150W-Amplifier

VIRE 150W Amplifier

  • Type: Class D Digital Stereo Board
  • Chipset: TPA3221 IC
  • Output: 150W + 150W Dual Channel
  • Voltage: DC 12V – 32V
  • Current: Up to 10A
  • Output Impedance: 4Ω – 8Ω
  • Aux Power: 5V output (for Bluetooth modules)
  • Cooling: Aluminum heatsink

12 zone console

  • Configuration: 12 separate zone selector buttons + 1 “All Call” switch
  • Microphone: Integrated 16-inch (40 cm) flexible gooseneck mic
  • Output Level: 1V Balanced nominal signal
  • Operating Voltage: DC 24V (powered by central system unit)
  • Indicators: Individual LED lights for active zone selection
  • Controls: Independent volume knobs for microphone and chime
  • Connectors: Heavy-duty 8-pin lockable interface
12-zone-console

12-zone-console

Table Top Mate (Adjustable Folding Table)

  • Adjustability: 6 height levels and 3 tilting angle positions
  • Top Surface: Virgin polymer plastic tray, roughly 24 x 18 inches
  • Frame: Powder-coated high-grade tubular steel legs
  • Weight Capacity: Safely holds up to 10 kg
  • Portability: Tool-free 2-minute assembly; folds flat for easy storage
  • Add-ons: Built-in slide-out cup holder
  • Design: U-shaped legs with no cross-braces to prevent leg-bumping

6W Ceiling Speaker

  • Rated Power: 6W RMS (Tappings at 6W, 3W, 1.5W)
  • Line Voltage: 100V (with matching transformer)
  • Frequency Range: 60Hz – 15,000Hz
  • Sensitivity: 92dB (1W / 1m)
  • Driver Size: 5-inch or 6-inch full-range cone
  • Enclosure Type: ABS plastic grill with metal clamp
  • Mounting: Spring-loaded ceiling clips

6W-Wall Mount-Speaker

6W Wall Mount Speaker​

  • Rated Power: 6W RMS (Tappings at 6W, 3W, 1.5W)
  • Line Voltage: 100V line matching transformer
  • Frequency Range: 150Hz – 15,000Hz
  • Sensitivity: 91dB (1W / 1m)
  • Driver Size: 4-inch or 5-inch full-range speaker
  • Enclosure Type: ABS plastic housing with steel mesh grille
  • Mounting: Rear keyhole slot or adjustable bracket

Addressable Panel

  • Capacity: Supports 1 to 2 loops, expandable.
  • Devices: Connects 125+ addressable points per loop.
  • Wiring: Class A or Class B SLC loop.
  • Interface: Alphanumeric LCD display with event logs.
  • Power: 24VDC with 24-hour backup battery.
  • Cabinet: Lockable, heavy-gauge steel enclosure.
  • Sensors: Intelligent smoke, heat, and monitor modules.
  • ID: Unique electronic or rotary device addressing.
  • Maintenance: Automatic drift compensation for dust.
  • NACs: Built-in circuits for horns/strobes.
  • Relays: Dry contacts for Alarm and Trouble.
Addressable-Panel

Fire-hooter

Fire hooter

  • Output: 90 to 120 dB at 1 meter.
  • Tone: Continuous siren or dual-tone pulse.
  • Voltage: 24V DC or 230V AC.
  • Body: Red fire-retardant ABS plastic.
  • Type: Wall-mounted (Sounder or Sounder-Strobe).
  • Rating: IP43 for indoors; IP65 for outdoors.

Addressable hooter

  • Voltage: 16–33 VDC (24 VDC nominal).
  • Current: <1 mA standby; 100–350 mA alarm.
  • Addressing: Digital (DIP switches or software).
  • Sound Level: 85 to 110 dB at 3 meters.
  • Tones: Field-selectable (continuous, pulsing, sweeping).
  • Strobe (Optional): LED/Xenon flash, 15 to 110 candela.
  • Material: Flame-retardant ABS plastic or Mild Steel.
  • Environment: -10°C to 50°C; up to 95% humidity.

Manual call point

  • Voltage: 24V DC nominal (9V to 30V range)
  • Current: Low standby (~0.5mA); high alarm (~30mA)
  • Material: Red, flame-retardant ABS plastic
  • IP Rating: IP24D for indoor; IP67 for outdoor
  • Operation: Break-glass or resettable plastic element
  • Standards: EN 54-11 or UL 38 compliance

Smoke detector

  • Sensor: Photoelectric (optical) for smouldering smoke.
  • Coverage: Up to 50–100 m² per detector.
  • Voltage: 9V–24V DC panel power or 9V battery.
  • Wiring: 2-wire or 4-wire (conventional/addressable).
  • Body: White fire-retardant ABS plastic.
  • LED: Blinks in standby; solid red for alarm.
Smoke-detector

Addressable-smoke-detector

Addressable smoke detector

  • Type: Photoelectric smoke sensor.
  • Power: Loop-powered (15–32 VDC).
  • Protocol: Digital addressable loop communication.
  • Addressing: Rotary switches or electronic ID.
  • LED: Visual status (Normal, Fault, and Alarm).
  • Dust Fix: Automatic drift compensation.
  • Base: Plugs into standard/isolator bases.
  • Wiring: Simple 2-wire connection.
  • Approval: UL 268 or EN 54-7.

Heat detector

  • Type: Fixed temp / Rate-of-Rise thermal.
  • Power: Loop-powered (15–32 VDC).
  • Protocol: Digital addressable loop.
  • ID: Rotary or electronic addressing.
  • Trigger: Alarms at 57°C (135°F).
  • LED: Visual Normal / Alarm status.
  • Base: Plugs into standard 2-wire base.
  • Approval: UL 521 or EN 54-5.
Heat-detector

Addressable-multi-sensor-detector

Addressable multi-sensor detector

  • Type: Photoelectric smoke + thermal heat.
  • Power: Loop-powered (15–32 VDC).
  • Protocol: Digital addressable loop.
  • ID: Rotary or electronic addressing.
  • Logic: Dual-criteria reduces false alarms.
  • LED: Visual Normal / Alarm status.
  • Base: Standard 2-wire plug-in base.
  • Approval: UL 268/521 or EN 54-29

Response Indicator

  • Input: 12–24VDC loop power.
  • Current: Under 10mA alarm current.
  • LED: High-visibility dual red LEDs.
  • Wiring: 2-wire polarity connection.
  • Link: Remote output of hidden detector.
  • Body: Flame-retardant ABS plastic casing.
  • Mount: Surface wall or ceiling installation.
  • Standard: IS 2189 / BS 5839.

Beam-detector

Beam detector

  • Voltage: 10.2 – 32 VDC
  • Current: 17mA standby / 38.5mA alarm
  • Range: 5 – 100 metres (16 – 328 feet)
  • Temperature: -30°C to 55°C (-22°F to 131°F)
  • Humidity: 10% – 93% RH
  • Sensitivity: 25% – 50% obscuration