Fire Alarm System
Fire alarm panel
- Size: 2, 4, 8, or 16 zones (conventional) or 1 to 4+ loops (addressable).
- Devices: Up to 32 devices per zone or 250 per loop.
- Mains: 230V AC, 50Hz primary power input.
- Backup: 24V DC battery setup with automatic charger.
- Body: Wall-mounted powder-coated MS sheet enclosure.
- Interface: LCD display with Reset, Silence, and Test keys
PA (Public Address); FA (Fire Alarm) Panel
- Integration: PA system links to the FA panel via NO/NC relay contacts for automated evacuation announcements.
- FA Panel Type: Addressable or Conventional (2/4/8/16+ zones) loop-based control system.
- FA Power & Backup: 230V AC mains input with a built-in 24V DC battery charger and 24-to-48-hour standby backup.
- PA Amplifier Output: 120W / 250W / 500W+ (70V / 100V line) options depending on zone speaker loads.
- PA Enclosure & Controls: 14/16 SWG wall-mounted rack with zoning switches, gooseneck fireman mic, and pre-recorded alert messages.
- Standards: Conforms to IS 2189 (FA system code) and NBC (National Building Code) requirements.
VIRE 150W Amplifier
- Type: Class D Digital Stereo Board
- Chipset: TPA3221 IC
- Output: 150W + 150W Dual Channel
- Voltage: DC 12V – 32V
- Current: Up to 10A
- Output Impedance: 4Ω – 8Ω
- Aux Power: 5V output (for Bluetooth modules)
- Cooling: Aluminum heatsink
12 zone console
- Configuration: 12 separate zone selector buttons + 1 “All Call” switch
- Microphone: Integrated 16-inch (40 cm) flexible gooseneck mic
- Output Level: 1V Balanced nominal signal
- Operating Voltage: DC 24V (powered by central system unit)
- Indicators: Individual LED lights for active zone selection
- Controls: Independent volume knobs for microphone and chime
- Connectors: Heavy-duty 8-pin lockable interface
Table Top Mate (Adjustable Folding Table)
- Adjustability: 6 height levels and 3 tilting angle positions
- Top Surface: Virgin polymer plastic tray, roughly 24 x 18 inches
- Frame: Powder-coated high-grade tubular steel legs
- Weight Capacity: Safely holds up to 10 kg
- Portability: Tool-free 2-minute assembly; folds flat for easy storage
- Add-ons: Built-in slide-out cup holder
- Design: U-shaped legs with no cross-braces to prevent leg-bumping
6W Ceiling Speaker
- Rated Power: 6W RMS (Tappings at 6W, 3W, 1.5W)
- Line Voltage: 100V (with matching transformer)
- Frequency Range: 60Hz – 15,000Hz
- Sensitivity: 92dB (1W / 1m)
- Driver Size: 5-inch or 6-inch full-range cone
- Enclosure Type: ABS plastic grill with metal clamp
- Mounting: Spring-loaded ceiling clips
6W Wall Mount Speaker
- Rated Power: 6W RMS (Tappings at 6W, 3W, 1.5W)
- Line Voltage: 100V line matching transformer
- Frequency Range: 150Hz – 15,000Hz
- Sensitivity: 91dB (1W / 1m)
- Driver Size: 4-inch or 5-inch full-range speaker
- Enclosure Type: ABS plastic housing with steel mesh grille
- Mounting: Rear keyhole slot or adjustable bracket
Addressable Panel
- Capacity: Supports 1 to 2 loops, expandable.
- Devices: Connects 125+ addressable points per loop.
- Wiring: Class A or Class B SLC loop.
- Interface: Alphanumeric LCD display with event logs.
- Power: 24VDC with 24-hour backup battery.
- Cabinet: Lockable, heavy-gauge steel enclosure.
- Sensors: Intelligent smoke, heat, and monitor modules.
- ID: Unique electronic or rotary device addressing.
- Maintenance: Automatic drift compensation for dust.
- NACs: Built-in circuits for horns/strobes.
- Relays: Dry contacts for Alarm and Trouble.
Fire hooter
- Output: 90 to 120 dB at 1 meter.
- Tone: Continuous siren or dual-tone pulse.
- Voltage: 24V DC or 230V AC.
- Body: Red fire-retardant ABS plastic.
- Type: Wall-mounted (Sounder or Sounder-Strobe).
- Rating: IP43 for indoors; IP65 for outdoors.
Addressable hooter
- Voltage: 16–33 VDC (24 VDC nominal).
- Current: <1 mA standby; 100–350 mA alarm.
- Addressing: Digital (DIP switches or software).
- Sound Level: 85 to 110 dB at 3 meters.
- Tones: Field-selectable (continuous, pulsing, sweeping).
- Strobe (Optional): LED/Xenon flash, 15 to 110 candela.
- Material: Flame-retardant ABS plastic or Mild Steel.
- Environment: -10°C to 50°C; up to 95% humidity.
Manual call point
- Voltage: 24V DC nominal (9V to 30V range)
- Current: Low standby (~0.5mA); high alarm (~30mA)
- Material: Red, flame-retardant ABS plastic
- IP Rating: IP24D for indoor; IP67 for outdoor
- Operation: Break-glass or resettable plastic element
- Standards: EN 54-11 or UL 38 compliance
Smoke detector
- Sensor: Photoelectric (optical) for smouldering smoke.
- Coverage: Up to 50–100 m² per detector.
- Voltage: 9V–24V DC panel power or 9V battery.
- Wiring: 2-wire or 4-wire (conventional/addressable).
- Body: White fire-retardant ABS plastic.
- LED: Blinks in standby; solid red for alarm.
Addressable smoke detector
- Type: Photoelectric smoke sensor.
- Power: Loop-powered (15–32 VDC).
- Protocol: Digital addressable loop communication.
- Addressing: Rotary switches or electronic ID.
- LED: Visual status (Normal, Fault, and Alarm).
- Dust Fix: Automatic drift compensation.
- Base: Plugs into standard/isolator bases.
- Wiring: Simple 2-wire connection.
- Approval: UL 268 or EN 54-7.
Heat detector
- Type: Fixed temp / Rate-of-Rise thermal.
- Power: Loop-powered (15–32 VDC).
- Protocol: Digital addressable loop.
- ID: Rotary or electronic addressing.
- Trigger: Alarms at 57°C (135°F).
- LED: Visual Normal / Alarm status.
- Base: Plugs into standard 2-wire base.
- Approval: UL 521 or EN 54-5.
Addressable multi-sensor detector
- Type: Photoelectric smoke + thermal heat.
- Power: Loop-powered (15–32 VDC).
- Protocol: Digital addressable loop.
- ID: Rotary or electronic addressing.
- Logic: Dual-criteria reduces false alarms.
- LED: Visual Normal / Alarm status.
- Base: Standard 2-wire plug-in base.
- Approval: UL 268/521 or EN 54-29
Response Indicator
- Input: 12–24VDC loop power.
- Current: Under 10mA alarm current.
- LED: High-visibility dual red LEDs.
- Wiring: 2-wire polarity connection.
- Link: Remote output of hidden detector.
- Body: Flame-retardant ABS plastic casing.
- Mount: Surface wall or ceiling installation.
- Standard: IS 2189 / BS 5839.
Beam detector
- Voltage: 10.2 – 32 VDC
- Current: 17mA standby / 38.5mA alarm
- Range: 5 – 100 metres (16 – 328 feet)
- Temperature: -30°C to 55°C (-22°F to 131°F)
- Humidity: 10% – 93% RH
- Sensitivity: 25% – 50% obscuration